Model: BTY-MB
Description:
Capacities:(Emax)
10,20,30,40,50,60,100t
Rated output:
2.0mV/V
Digital:1,000,000d
Accuracy: C3 OIML R60
Material of elastomer: Alloy steel or stainless steel
Execution standard:
GB/T 7551-1997 Certificate
(eqv OIML R60)
Combined error: 0.015%
Sealed to IEC 529:
Protection grade: IP67 or IP68.
Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water.
Dimensions
(In mm. 1mm = 0.03937 inches)
Circuit Diagram:
Electrical Termination
4 Core cable standard lengths:
<=30t: 12.0 m, >=50t: 18m
Diameter:Φ6
Connection: Refer to the following drawing:
Notice:
Do not change the length of cable, or lese, it will effect the sensitivity of load cell.
Specification
Item\ Parameter
|
C3
|
Unit
|
Rated load (Emax):
|
10,20,30,40,50,60,100
|
t
|
Maximal numbers of load cell verification
Intervals (Nlc):
|
3000
|
d
|
Minimum load cell verification intervals
Intervals ( Vmin):
|
0.01
|
% of rated load
|
Rated output (Cn):
|
2.0±0.1%
|
mV/V
|
Combined error:
|
0.015
|
-% of rated output
|
Temperature effect on sensitivity(Tkc):
|
0.0012
|
=% of rated output/
|
Temperature effect on zero balance(Tk0):
|
0.0008
|
-% of rated output
|
Zero balance:
|
1.0
|
-% of rated output
|
Input resistance(Rlc):
|
775±5
|
Ω(Ohms)
|
Output resistance(Ro):
|
702±2
|
Ω(Ohms)
|
Insulation resistance:
|
≥5000
|
MΩ (Mega-Ohms)
|
Safe overload:
|
150
|
% of rated capability
|
Ultimate overload:
|
300
|
% of rated capability
|
Operating temperature range:
|
-20~+70/-20~+160
|
℃/ °F
|
Recommend excitation:
|
8~15
|
V( DC or AC)
|
Maximum excitation:
|
24
|
V( DC or AC)
|
Material of elastomer:
|
Alloy steel / Stainless steel
|
Protection class:
|
IP67/IP68
|
The data for deviation of synthesis error,TK0,TKc are typicl values. The sum of these
data meets the requirements according to OIML R60
|